Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell CC-PDOD51 Series C 24VDC Digital Output Module SINK Open Drain Coated

Quantity

Product Description

Description

The Honeywell CC-PDOD51 is a 32-channel, 24VDC digital output module designed for process switching applications within the Experion C300 Series C I/O architecture. Functioning as an open-drain SINK-type output card, this module allows the system to switch field loads by pulling the return path to ground, operating seamlessly with user-supplied field power supplies up to 30 VDC. The assembly comes conformal coated to protect internal electronic circuits against corrosive elements and harsh environmental contaminants commonly found in industrial processing plants.

Designed for cabinet density and reliable execution in DCS installations, the CC-PDOD51 plugs directly into its designated Input Output Termination Assembly (IOTA). It eliminates the need for separate chassis housing, receiving its operational logic power directly through the carrier bus. The module features integrated electronic overcurrent protection on every channel, eliminating the maintenance overhead associated with traditional inline fuses. It also provides configurable safe-state (FAILOPT) behaviors, enabling each output channel to either hold its last value or shed to a predetermined safe value in the event of system communication loss or controller failure.

Operating across 32 discrete output channels, the module supports flexible switching functions including latched, pulsed, and pulse-width modulated (PWM) outputs. To preserve signal integrity between field circuits and control logic, the Honeywell CC-PDOD51 maintains 1000 VAC RMS galvanic isolation between field power loops and the core system backplane. When deployed on redundant IOTA base units, the hardware delivers seamless switchover capability with zero output current gap, ensuring continuous process operations for critical actuators, interposing relays, and solenoid valves.

Features

  • 32-Channel SINK Configuration: Operates as an open-drain discrete output card designed to switch 24VDC field loads up to 0.1 A per channel.
  • Conformal Coating: Factory-coated internal circuitry provides resistance against airborne pollutants, industrial moisture, and corrosive atmospheric contaminants.
  • Electronic Overcurrent Protection: Features integrated current-limiting hardware to safeguard field wiring and channel drivers without requiring physical fuses.
  • Configurable Safe-State (FAILOPT): Allows per-channel programming to either Hold Last Value or Shed to Safe Value during system communication faults.
  • Versatile Switching Modes: Supports latched, pulsed, or pulse-width modulated (PWM) signal generation tailored to process control hardware.
  • Galvanic Isolation: Provides 1000 VAC RMS isolation between field-supplied power circuits and the system architecture.
  • Zero-Gap Switchover: Eliminates output current dropping (0 ms gap) during redundancy failover when installed on dual-IOM base units.

Applications

  • Solenoid Valve Actuation: Control and switching of 24VDC pneumatic and hydraulic solenoid coils in process skids.
  • Interposing Relay Logic: Interfacing low-current DCS output signals with higher-voltage motor control centers (MCC) and field equipment.
  • Annunciator & Pilot Light Control: Driving cabinet status indicators, local alarm horns, and visual display panels.
  • Discrete Skid Integration: Switching discrete actuators and equipment run/stop commands within Experion C300 control networks.

Technical Specifications

General

Parameter Specification
Manufacturer Honeywell
Model Number CC-PDOD51
Product Series Series C I/O
Product Type SINK Type 24VDC Digital Output Module
Protective Coating Coated (Conformal)
Shipping Weight 3.0 kg

Input / Output Characteristics

Parameter Specification
Output Channels 32
Output Type SINK (Open Drain)
Maximum Load Voltage 30 VDC
Minimum Load Voltage 15 VDC
Maximum Load Current 0.1 A per channel
On-State Voltage 0 VDC (at 0.1 A max load current)
Off-State Voltage 24 VDC (typical)
Off-State Leakage Current 100 uA (maximum)
Turn-On / Turn-Off Time 10 ms (maximum)
Switchover Gap (Redundancy) 0 ms (None)
Output Functions Latched, Pulsed, Pulse-Width Modulated (per channel)

Electrical & Isolation

Parameter Specification
Galvanic Isolation 1000 VAC RMS (System-to-Field isolation)
Power Source User-supplied field power
Short Circuit Protection Electronic overcurrent protection

IOTA Compatibility

Parameter Specification
Non-Redundant IOTA Model CC-TDOD51 (9-inch / 228 mm)
Redundant IOTA Model CC-TDOD61 (12-inch / 304 mm)

Installation Guidelines

  1. Pre-Installation Inspection: Verify the module part number (CC-PDOD51) and check that the physical enclosure and connector pins show no shipping damage.
  2. IOTA Mounting: Ensure the target IOTA (CC-TDOD51 or CC-TDOD61) is securely installed onto the cabinet enclosure rails and properly bonded to system ground.
  3. Field Power Wiring: Connect the external 24VDC user field power supply to the designated terminals on the IOTA assembly, maintaining correct polarity.
  4. Field Load Termination: Land field wiring onto the detachable two-level IOTA terminal blocks. Ensure wire sizes do not exceed 12 AWG (2.5 mm stranded).
  5. Module Insertion: Align the CC-PDOD51 module with the guide connectors on the IOTA and press firmly until the locking mechanism engages.
  6. Grounding & Shielding: Confirm overall cabinet ground continuity to prevent common-mode voltage fluctuations from impacting field circuits.

Configuration & Commissioning

  • Channel Parameterization: Assign individual channel operation parameters (latched, pulsed, or PWM) within the Experion Engineering Studio environment.
  • FAILOPT Behavior Setup: Configure safe-state parameters on a per-channel basis, defining whether outputs hold their last valid state or transition to a safe zero/off condition upon system failure.
  • Field Loop Testing: Perform point-to-point output verification from the control software, observing channel switching performance and load current across active field devices.
  • Redundancy Verification: If installed in a dual-module configuration on a CC-TDOD61 IOTA, perform a manual failover check to ensure continuous load state retention without signal interruption.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary difference between a SINK output module like CC-PDOD51 and a Source output module?
The CC-PDOD51 SINK module utilizes an open-drain output architecture that switches the ground side of the load loop, pulling the return path to 0 VDC when energized. In contrast, sourcing modules switch the positive 24VDC potential to the load. SINK output configurations are common when interfacing with loads that share a common positive power rail.
Which IOTA models are compatible with the Honeywell CC-PDOD51 module?
The module mounts on the CC-TDOD51 IOTA for non-redundant applications, which measures 9 inches (228 mm) in width. For redundant control setups, it installs on the CC-TDOD61 IOTA, which measures 12 inches (304 mm) in width.
Does the CC-PDOD51 digital output card require physical field fuses?
No, physical fuses are not required. The module features integrated electronic overcurrent protection that protects internal drivers and field wiring against short circuits, reducing maintenance costs and cabinet space requirements.
How does the module behave during a controller communication loss or failure?
Each of the 32 channels can be configured with individual FAILOPT (safe-state) settings. Depending on system requirements, individual outputs can be programmed to either hold their last valid state or shed to a pre-configured safe state.
Reviews

CC-PDOD51

Stock & lead time on request

Call
1 of 5

Honeywell CC-PDOD51 Series C 24VDC Digital Output Module SINK Open Drain Coated

Only 4 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: CC-PDOD51

  • Country of origin:United States

  • Product Type: Digital Output Modules

  • Payment: T/T, Western Union

  • Weight: 350g

  • Dimensions: 139 mm x 32 mm x 132 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Honeywell CC-PDOD51 is a 32-channel, 24VDC digital output module designed for process switching applications within the Experion C300 Series C I/O architecture. Functioning as an open-drain SINK-type output card, this module allows the system to switch field loads by pulling the return path to ground, operating seamlessly with user-supplied field power supplies up to 30 VDC. The assembly comes conformal coated to protect internal electronic circuits against corrosive elements and harsh environmental contaminants commonly found in industrial processing plants.

Designed for cabinet density and reliable execution in DCS installations, the CC-PDOD51 plugs directly into its designated Input Output Termination Assembly (IOTA). It eliminates the need for separate chassis housing, receiving its operational logic power directly through the carrier bus. The module features integrated electronic overcurrent protection on every channel, eliminating the maintenance overhead associated with traditional inline fuses. It also provides configurable safe-state (FAILOPT) behaviors, enabling each output channel to either hold its last value or shed to a predetermined safe value in the event of system communication loss or controller failure.

Operating across 32 discrete output channels, the module supports flexible switching functions including latched, pulsed, and pulse-width modulated (PWM) outputs. To preserve signal integrity between field circuits and control logic, the Honeywell CC-PDOD51 maintains 1000 VAC RMS galvanic isolation between field power loops and the core system backplane. When deployed on redundant IOTA base units, the hardware delivers seamless switchover capability with zero output current gap, ensuring continuous process operations for critical actuators, interposing relays, and solenoid valves.

Features

  • 32-Channel SINK Configuration: Operates as an open-drain discrete output card designed to switch 24VDC field loads up to 0.1 A per channel.
  • Conformal Coating: Factory-coated internal circuitry provides resistance against airborne pollutants, industrial moisture, and corrosive atmospheric contaminants.
  • Electronic Overcurrent Protection: Features integrated current-limiting hardware to safeguard field wiring and channel drivers without requiring physical fuses.
  • Configurable Safe-State (FAILOPT): Allows per-channel programming to either Hold Last Value or Shed to Safe Value during system communication faults.
  • Versatile Switching Modes: Supports latched, pulsed, or pulse-width modulated (PWM) signal generation tailored to process control hardware.
  • Galvanic Isolation: Provides 1000 VAC RMS isolation between field-supplied power circuits and the system architecture.
  • Zero-Gap Switchover: Eliminates output current dropping (0 ms gap) during redundancy failover when installed on dual-IOM base units.

Applications

  • Solenoid Valve Actuation: Control and switching of 24VDC pneumatic and hydraulic solenoid coils in process skids.
  • Interposing Relay Logic: Interfacing low-current DCS output signals with higher-voltage motor control centers (MCC) and field equipment.
  • Annunciator & Pilot Light Control: Driving cabinet status indicators, local alarm horns, and visual display panels.
  • Discrete Skid Integration: Switching discrete actuators and equipment run/stop commands within Experion C300 control networks.

Technical Specifications

General

Parameter Specification
Manufacturer Honeywell
Model Number CC-PDOD51
Product Series Series C I/O
Product Type SINK Type 24VDC Digital Output Module
Protective Coating Coated (Conformal)
Shipping Weight 3.0 kg

Input / Output Characteristics

Parameter Specification
Output Channels 32
Output Type SINK (Open Drain)
Maximum Load Voltage 30 VDC
Minimum Load Voltage 15 VDC
Maximum Load Current 0.1 A per channel
On-State Voltage 0 VDC (at 0.1 A max load current)
Off-State Voltage 24 VDC (typical)
Off-State Leakage Current 100 uA (maximum)
Turn-On / Turn-Off Time 10 ms (maximum)
Switchover Gap (Redundancy) 0 ms (None)
Output Functions Latched, Pulsed, Pulse-Width Modulated (per channel)

Electrical & Isolation

Parameter Specification
Galvanic Isolation 1000 VAC RMS (System-to-Field isolation)
Power Source User-supplied field power
Short Circuit Protection Electronic overcurrent protection

IOTA Compatibility

Parameter Specification
Non-Redundant IOTA Model CC-TDOD51 (9-inch / 228 mm)
Redundant IOTA Model CC-TDOD61 (12-inch / 304 mm)

Installation Guidelines

  1. Pre-Installation Inspection: Verify the module part number (CC-PDOD51) and check that the physical enclosure and connector pins show no shipping damage.
  2. IOTA Mounting: Ensure the target IOTA (CC-TDOD51 or CC-TDOD61) is securely installed onto the cabinet enclosure rails and properly bonded to system ground.
  3. Field Power Wiring: Connect the external 24VDC user field power supply to the designated terminals on the IOTA assembly, maintaining correct polarity.
  4. Field Load Termination: Land field wiring onto the detachable two-level IOTA terminal blocks. Ensure wire sizes do not exceed 12 AWG (2.5 mm stranded).
  5. Module Insertion: Align the CC-PDOD51 module with the guide connectors on the IOTA and press firmly until the locking mechanism engages.
  6. Grounding & Shielding: Confirm overall cabinet ground continuity to prevent common-mode voltage fluctuations from impacting field circuits.

Configuration & Commissioning

  • Channel Parameterization: Assign individual channel operation parameters (latched, pulsed, or PWM) within the Experion Engineering Studio environment.
  • FAILOPT Behavior Setup: Configure safe-state parameters on a per-channel basis, defining whether outputs hold their last valid state or transition to a safe zero/off condition upon system failure.
  • Field Loop Testing: Perform point-to-point output verification from the control software, observing channel switching performance and load current across active field devices.
  • Redundancy Verification: If installed in a dual-module configuration on a CC-TDOD61 IOTA, perform a manual failover check to ensure continuous load state retention without signal interruption.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell CC-PDOD51 Series C 24VDC Digital Output Module SINK Open Drain Coated

What is the primary difference between a SINK output module like CC-PDOD51 and a Source output module?

The CC-PDOD51 SINK module utilizes an open-drain output architecture that switches the ground side of the load loop, pulling the return path to 0 VDC when energized. In contrast, sourcing modules switch the positive 24VDC potential to the load. SINK output configurations are common when interfacing with loads that share a common positive power rail.

Which IOTA models are compatible with the Honeywell CC-PDOD51 module?

The module mounts on the CC-TDOD51 IOTA for non-redundant applications, which measures 9 inches (228 mm) in width. For redundant control setups, it installs on the CC-TDOD61 IOTA, which measures 12 inches (304 mm) in width.

Does the CC-PDOD51 digital output card require physical field fuses?

No, physical fuses are not required. The module features integrated electronic overcurrent protection that protects internal drivers and field wiring against short circuits, reducing maintenance costs and cabinet space requirements.

How does the module behave during a controller communication loss or failure?

Each of the 32 channels can be configured with individual FAILOPT (safe-state) settings. Depending on system requirements, individual outputs can be programmed to either hold their last valid state or shed to a pre-configured safe state.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...