Description

Facilitating high-performance visualization at extended physical distances, the Beckhoff C9900-F305 serves as an integrated DVI/USB Extended interface option for industrial Control Panels. This interface module overcomes standard cable limitations by converting visual and input signals for transmission over long distances, allowing the operator interface to be positioned directly at the machine while the industrial PC remains protected within a centralized control cabinet. Utilizing robust physical connectors, the C9900-F305 ensures lag-free display updates and reliable peripheral data rates across the entire connection span.

Features

  • Extended Range Connectivity: Integrates DVI-E and USB-E 2.0 technologies to transmit video and USB signals up to 50 meters without signal degradation.
  • High-Speed USB Transmission: Supports USB-E 2.0 protocol with physical layer transfer rates reaching up to 480 Mbit/s.
  • Standard Compatibility: DVI-E input remains completely compatible with standard PC DVI graphics outputs when used with appropriate transmitter units.
  • Direct Connection Interface: Features a standard USB 2.0 input for short-range configurations (up to 5 meters) directly to standard PC USB ports.
  • Integrated Hub: Provides downstream USB 2.0 ports at the panel for direct connection of human interface devices (HID) like keyboards, mice, or flash storage.

Applications

  • Automotive Assembly Lines: Separation of control PCs from harsh vibration zones on the factory floor while retaining local operator control.
  • Cleanroom Environments: Housing processing units outside controlled zones while routing thin, easily-sealed cables to the local display interface.
  • Distributed HMI Topographies: Applications requiring multi-station visualization connected to a single, high-performance master industrial PC.

Technical Specifications

Manufacturer Beckhoff
Model / Article Number C9900-F305
Interface Technology DVI-E (DVI Extended) and USB-E 2.0 (USB Extended)
Maximum Distance (Extended) 50 meters (using specialized DVI-E/USB-E cabling)
Maximum Distance (Standard) 5 meters (direct standard USB 2.0 connection)
Data Transmission Rate Up to 480 Mbit/s (USB 2.0 speed limit via USB-E)
Operating Voltage 24 V DC (supplied via Control Panel power link)
Operating Temperature Range 0 to 55 degC
Protection Rating (Front Side) IP65 (when correctly integrated into matching front housing)
Protection Rating (Rear Side) IP20
Shipping Weight (Calculated) 3.0 kg
Package Dimensions (Calculated) 350 mm x 280 mm x 120 mm

Connections and Interfaces

Port / Connector Interface Type Functional Assignment
DVI Input DVI-D Female Receives digital video signals from the PC transmitter unit.
RJ45 Port RJ45 Cat.6/Cat.7 Connection Extends USB-E 2.0 communication up to 50 meters to host PC.
USB 2.0 Input USB Type B Direct local connection to host PC (up to 5 meters maximum).
USB Downstream 2 x USB 2.0 Type A Local peripheral connections (e.g., flash drive, keyboard, mouse).

Empirical Engineering Insights

Alternative Models & Compatibility

The C9900-F305 is specifically designed to match CP69xx built-in Control Panels or corresponding custom industrial monitors from Beckhoff. When retrofitting older setups, verify that the transmitter module on the industrial PC side (such as a CU8801 or matching PCIe transmitter card) supports the same USB-E 2.0 specifications to prevent baud-rate downshifting or device dropouts.

Application Pitfalls & Engineering Notes

While standard RJ45 networking hardware is used for physical connectivity of the USB-E 2.0 signal, this path is not an Ethernet network. Do not route the USB-E 2.0 RJ45 cable through network switches, hubs, or routers. Doing so will permanently damage the active routing hardware and prevent transmission. Always use a continuous, direct physical cable between the transmitter and the C9900-F305 module.

Commissioning & Wiring Tips

For installations approaching the 50-meter limit, use highly shielded Cat.7 STP (Shielded Twisted Pair) cables with metallic RJ45 plugs. Grounding the shield properly at the panel entry point is crucial to suppress EMI from adjacent VFD motor lines or high-voltage power paths within the cable tray.

Installation Guidelines

CRITICAL WARNING: electrical isolation

Disconnect all 24 V DC power supplies before initiating panel installation or cable modification. Verify that the system's power supply is fully de-energized to prevent ESD or sudden voltage spikes across the active DVI-E and USB-E interface transceiver chips.

1
Mechanical Mounting: Secure the Control Panel housing into the machine cutout using the pull-out clamping levers. Ensure the IP65 rubber sealing ring on the front bezel lies flat against the clean mounting surface.
2
DVI-E Video Routing: Connect the dedicated DVI-E cable to the DVI input port. Ensure the locking screws on the DVI connector are tightened hand-tight to secure electrical shield continuity.
3
USB-E Extension Hookup: Terminate your shielded Cat.7 line into the RJ45 port for long-distance USB extension. For setups within 5 meters, bypass this and use the USB Type B input connected directly to the IPC.
4
Power Supply Initialization: Secure the 24 V DC supply leads to the terminal strip block. Confirm correct polarity (+24V, 0V, and Ground/PE) before restoring supply power.
Loading product navigation…

What is the maximum cable distance supported by the C9900-F305?

The C9900-F305 supports transmission distances of up to 50 meters between the host industrial PC and the Control Panel using DVI-E and USB-E 2.0 configurations.

Can I route the USB-E 2.0 RJ45 cable through an active network switch?

No. The USB-E 2.0 signal uses standard RJ45 physical cabling but is not an IP protocol. Direct point-to-point connection is required; connecting to network hardware will cause hardware damage.

Does this interface require separate auxiliary power?

The interface operates on the integrated 24 V DC power input supplied to the main Control Panel assembly, ensuring simplified terminal field wiring.

What kind of cable is recommended for the 50-meter run?

High-quality, shielded Cat.7 STP (Shielded Twisted Pair) copper cabling with metal-shielded RJ45 terminations is recommended to maintain reliable communication rates in noisy EMI environments.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...