Designed for DIN rail installation, the Beckhoff CX2020-0113 basic CPU module functions as the core processing unit within the CX2000 Embedded PC series. This controller is equipped with an Intel Celeron processor and runs the Windows Embedded Compact 7 operating system with TwinCAT 2 NC I runtime pre-installed. It integrates direct backplane connections for Beckhoff I/O systems, supporting automatic recognition of both E-bus (EtherCAT) and K-bus (Bus Terminal) terminals. The module's hardware layout is designed for reliable execution of precise motion control and automation sequences under varying industrial conditions.

Features

  • Intel Celeron 827E 1.4 GHz single-core processor for stable industrial processing.
  • Standard 2 GB DDR3 RAM, expandable ex factory to 4 GB.
  • Integrated 128 kB NOVRAM for non-volatile data retention during power interruption.
  • Dual independent RJ45 Gigabit Ethernet ports alongside four USB 2.0 interfaces.
  • Direct I/O connection with automatic, system-level recognition of E-bus and K-bus lines.
  • Passive heat-sink cooling design, with options for factory-fitted active cooling.

Applications

  • Multi-axis coordinated motion control and CNC machining stations.
  • Automated assembly systems and sorting lines.
  • HVAC and smart building control systems.
  • High-speed process automation using EtherCAT decentralized networks.

Technical Specifications

Manufacturer Beckhoff
Model / Part Number CX2020-0113
Processor Intel Celeron 827E 1.4 GHz (1 Core)
Main Memory 2 GB DDR3 RAM (expandable to 4 GB ex factory)
Flash Memory 20 GB or 40 GB CFast card (depending on operating system)
Persistent Memory 128 kB NOVRAM integrated
Interfaces 2 x RJ45 10/100/1000 Mbit/s, 1 x DVI-I, 4 x USB 2.0, 1 x optional slot
Operating System Windows Embedded Compact 7
Control Software TwinCAT 2 NC I runtime
TwinCAT 3 Platform Level Performance Plus (50)
Power Supply 24 V DC (-15% / +20%)
Max. Power Consumption 21 W
Cooling Passive (optionally active ex factory)
IP Rating IP20
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Dimensions (W x H x D) 144 mm x 99 mm x 91 mm
Weight approx. 1160 g

Connections and Interfaces

Interface Connector Function Type
2 x RJ45 10/100/1000 Mbit/s Gigabit Ethernet ports
1 x DVI-I Video signal and monitor output connection
4 x USB 2.0 Peripheral connection interfaces
Optional Slot Configurable factory-fitted fieldbus or communication interface

Installation Guidelines

  • Mounting: Snap securely onto a standard 35 mm DIN rail (EN 60715). Ensure the mounting clip engages fully.
  • Ventilation: Mount horizontally within the control cabinet. Maintain free space of at least 30 mm above and below the module for unhindered air circulation.
  • Grounding: Ensure a low-resistance connection to the functional earth is established through the DIN rail or backplane connection.
  • Wiring: Confirm input power supply parameters conform strictly to 24 V DC requirements before energizing the module.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What operating system and control software come pre-configured with the CX2020-0113?

The CX2020-0113 is supplied with Windows Embedded Compact 7 pre-installed, configured with the TwinCAT 2 NC I runtime platform.

Does this basic CPU module support both K-bus and E-bus terminals?

Yes. When coupled with an appropriate power supply module, the CX2020-0113 automatically recognizes and communicates with both K-bus (Bus Terminals) and E-bus (EtherCAT Terminals).

Is the cooling on the CX2020-0113 active or passive?

The standard CX2020-0113 relies on a passive cooling design. However, an active cooling option can be configured ex factory depending on your system's deployment environment.

Does the unit contain non-volatile memory for retaining data on power loss?

Yes, the module features an integrated 128 kB NOVRAM for persistent, non-volatile data storage.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...