1 of 1

EL3008 | BECKHOFF | Terminal EtherCAT

EL3008 | BECKHOFF | Terminal EtherCAT

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : EL3008

  • Pays d'origine :Allemagne

  • Type de produit : Bornier EtherCAT

  • Paiement : Virement bancaire, Western Union

  • Poids : 70g

  • Dimensions : 12 mm x 100 mm x 68 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for high-density analog signal acquisition, the EL3008 EtherCAT Terminal processes up to eight single-ended voltage signals in the range of -10 V to +10 V. Each analog input channel features a 12-bit resolution, mapped into a 16-bit process image (including sign representation) for standard compatibility with EtherCAT control environments. Powered directly through the E-bus, this compact 12 mm module provides electrical isolation between the internal E-bus circuitry and the field-side signal lines to ensure high signal integrity and system robustness in demanding electrical environments.

The EL3008 features configurable conversion times and built-in digital filters (FIR/IIR) to help suppress high-frequency noise and match system-specific acquisition requirements. Integrating limit value monitoring and overload detection directly within the process data, this module simplifies diagnosis and monitoring tasks for modern PLC, DCS, and industrial automation networks.

Features

  • Eight independent single-ended analog input channels in a compact terminal housing.
  • Voltage measurement range from -10 V to +10 V with 12-bit conversion resolution.
  • Fast internal conversion time with a default rate of 1.25 ms (configurable and multiplexed).
  • Integrates software-activatable FIR and IIR filters for effective signal conditioning.
  • Advanced diagnostics including limit value monitoring and channel-specific overload indication in process data.
  • Robust electrical isolation of 500 V between the E-bus and signal channels.
  • High-density spring-loaded cage connection system for quick and secure field wiring.

Applications

  • Multi-point voltage monitoring in process plants and manufacturing systems.
  • Sensor and transducer data acquisition in factory automation.
  • Control loop feedback in mechanical engineering and test benches.
  • Sub-assembly integration within centralized EtherCAT I/O architectures.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model EL3008
Product Type EtherCAT Terminal (Analog Input Module)
Number of Inputs 8 (single-ended)
Signal Voltage Range -10 V to +10 V
Resolution 12 bit (16 bit representation including sign)
Power Supply Via the E-bus
Current Consumption (E-bus) Typical 130 mA
Internal Resistance Greater than 130 kOhm
Input Filter Limit Frequency 1 kHz
Dielectric Strength Max. 30 V
Conversion Time 1.25 ms (default setting, configurable, multiplexed)
Measuring Error Less than +/-0.3% (relative to full scale value)
Electrical Isolation 500 V (E-bus / signal voltage)
Process Image Width 32 bytes (inputs)
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approx. 70 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Installation Position Variable

Connections and Interfaces

Connection Type Conductor Specifications
Solid Wire Cross-section 0.08 mm² to 2.5 mm² (AWG 28 to 14)
Stranded Wire Cross-section 0.08 mm² to 2.5 mm² (AWG 28 to 14)
Wire with Ferrule 0.14 mm² to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 mm to 9 mm
Actuation Method Screwdriver-actuated spring tension clamp

Installation Guidelines

  • Mounting: Mount on a standard 35 mm DIN rail conforming to EN 60715. Ensure the locking latch engages securely.
  • Side-by-Side Placement: Use the double slot and key connection system to line up adjacent terminals securely.
  • Wiring: Always use an appropriate screwdriver to actuate the spring contacts when inserting solid, stranded, or ferruled conductors. Ensure stripping length matches the 8–9 mm specification to prevent exposed conductors.
  • Environment: The unit is rated IP20. Ensure it is installed in a dust-free and dry control cabinet or enclosure to prevent condensation and environmental contamination.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 / EN 60068-2-27
Loading product navigation…

Does the Beckhoff EL3008 support Distributed Clocks (DC)?

No, the EL3008 terminal does not feature Distributed Clocks support. It transmits process data in sync with the EtherCAT cycle.

What is the measuring range and input impedance of the EL3008?

The EL3008 has a signal voltage input range of -10 V to +10 V, with an input internal resistance of greater than 130 kOhm.

What wire sizes are compatible with the connection terminals of the EL3008?

The spring-tension terminal blocks accommodate solid and stranded wires from 0.08 to 2.5 mm² (AWG 28–14) and wires with ferrules from 0.14 to 1.5 mm² (AWG 26–16).

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...