Designed for high-precision analog acquisition within EtherCAT networks, the EL3164 analog input terminal processes signal voltages ranging from 0 to 10 V. This four-channel module features a single-ended design configuration, converting analog process signals with 16-bit resolution (including sign) for transmission to the higher-level automation controller. Built for industrial environments, it features integrated Distributed Clocks (DC) to ensure highly synchronized microsecond-level timing across the control system.

The EL3164 EtherCAT terminal integrates configurable software options to optimize signal quality, including selectable FIR and IIR digital filters, along with limit value monitoring capabilities. This compact 12 mm module communicates directly via the E-bus to leverage high-speed data transfer rates, making it an ideal choice for testing, assembly, and plant automation applications.

Features

  • Four independent, single-ended analog input channels in a single compact housing
  • Standard signal voltage range of 0 to 10 V
  • High-resolution 16-bit analog-to-digital conversion (including sign)
  • Supports Distributed Clocks (DC) for precise synchronization across the network
  • Software-configurable digital filters (FIR/IIR) and integrated limit value monitoring
  • Electrical isolation of 500 V between the E-bus and the input signal channels
  • Standard compact design with status indication LEDs for fast diagnostic troubleshooting

Applications

  • Heavy industrial process monitoring and automation control loops
  • Precision machine building and high-speed motion synchronization
  • Data acquisition setups, calibration platforms, and automated test benches
  • Automated HVAC control, water distribution, and environmental monitoring infrastructure

Technical Specifications

Manufacturer Beckhoff
Part Number / Model EL3164
Number of Inputs 4 (single-ended)
Signal Voltage Range 0 to 10 V
Resolution 16 bit (incl. sign)
Conversion Time approx. 100 us
Internal Resistance > 200 kOhm
Input Filter Limit Frequency 5 kHz
Dielectric Strength max. 30 V
Measuring Error < +/-0.3 % (relative to full scale value)
Distributed Clocks Yes
Current Consumption E-bus typ. 130 mA
Electrical Isolation 500 V (E-bus / signal voltage)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, non-condensing
Protection Rating IP20
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight approx. 65 g

Connections and Interfaces

Conductor Type Connection Cross-Section (Metric) Connection Cross-Section (AWG)
Solid Wire (s) 0.08 to 2.5 mm² AWG 28 to 14
Stranded Wire (st) 0.08 to 2.5 mm² AWG 28 to 14
With Ferrule (f) 0.14 to 1.5 mm² AWG 26 to 16
Stripping Length 8 to 9 mm

Installation Guidelines

  • Mounting: Snap directly onto a standard 35 mm DIN rail (conforming to EN 60715). Ensure the locking mechanism is engaged.
  • Shielding and Grounding: Connect the cable shield directly to the grounding busbar or ground terminal to minimize electromagnetic noise on the analog inputs.
  • Wiring: Toolless wiring can be performed on solid or ferruled wires using the integrated spring-clamp terminals. For stranded wires without ferrules, actuate the clamp using a small screwdriver.
  • Environmental: Install in a dry, clean cabinet environment with an ambient operating temperature between 0 and +55 degC. Ensure ventilation clearance as required by system architecture guidelines.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
Loading product navigation…

What is the signal voltage range for the Beckhoff EL3164?

The EL3164 processes single-ended analog voltage signals within the range of 0 to 10 V.

Does the EL3164 support Distributed Clocks (DC)?

Yes, the EL3164 terminal supports Distributed Clocks, allowing highly precise synchronization with other network components.

What is the measurement resolution of this module?

The EL3164 provides a high measurement resolution of 16 bits, which includes the sign bit.

What is the typical current consumption of the EL3164 from the E-bus?

The module typically draws 130 mA from the E-bus power supply.

What ATEX hazardous area classification does the EL3164 have?

The module is certified with ATEX marking II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous locations.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...