1 of 1

EL4112-0010 | BECKHOFF | Bornier EtherCAT

EL4112-0010 | BECKHOFF | Bornier EtherCAT

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : EL4112-0010

  • Pays d'origine :Allemagne

  • Type de produit : Bornier EtherCAT

  • Paiement : Virement bancaire, Western Union

  • Poids : 65g

  • Dimensions : 12 mm x 100 mm x 68 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Engineered for precision industrial control loops, the EL4112-0010 analog output terminal generates standard electrical current signals in the range of -10 to +10 mA. This analog output terminal processes process data from the automation device with a high resolution of 16 bits (including sign) and transmits it with galvanic isolation directly to the field level. It features integrated Distributed Clocks (DC) support, allowing for highly synchronized, microsecond-level updates across EtherCAT networks.

The system features a 3-wire, single-ended connection technology, making it compatible with a wide array of industrial actuators, control valves, and system drives. With parameterized watchdog functionality and customizable user synchronization, this module delivers stable performance and safe-state fallback options for critical machinery systems.

Features

  • Provides two independent analog output channels with a current range of -10 to +10 mA.
  • Delivers high-precision digital-to-analog conversion at 16-bit resolution (including sign).
  • Supports EtherCAT Distributed Clocks (DC) with synchronization precision under 1 microsecond.
  • Includes short-circuit-proof outputs compatible with loads up to 500 Ohm.
  • Features integrated parameterizable watchdog state and user-activatable synchronization.
  • Constructed with a compact, rugged housing requiring only 12 mm of DIN rail width.

Applications

  • Closed-loop hydraulic and pneumatic valve positioning
  • Variable speed motor drive control systems
  • Distributed industrial process automation and telemetry
  • Power generation and turbine control auxiliary systems

Technical Specifications

Manufacturer Beckhoff
Part Number / Model EL4112-0010
Number of Outputs 2
Signal Current -10 to +10 mA
Resolution 16 bit (incl. sign)
Connection Technology 3-wire, single-ended
Power Supply 24 V DC via power contacts
Current Consumption E-bus typ. 160 mA
Current Consumption Power Contacts typ. 15 mA + load
Process Image Bit Width 2 x 16 bit AO output
Maximum Output Rate 15 ksps
Load < 500 Ohm (short-circuit proof)
Measuring / Output Error < +-0.1% (relative to end value)
Electrical Isolation 500 V (E-bus / signal voltage)
Distributed Clocks Yes (precision << 1 microsecond)
Housing Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight approx. 65 g
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Relative Humidity 95%, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20

Connections and Interfaces

Connection Type Conductor Cross-Section AWG Range Stripping Length
Solid Wire (s) 0.08 to 2.5 mm² AWG 28 to 14 8 to 9 mm
Stranded Wire (st) 0.08 to 2.5 mm² AWG 28 to 14 8 to 9 mm
With Ferrule (f) 0.14 to 1.5 mm² AWG 26 to 16 8 to 9 mm

Installation Guidelines

  • Mount vertically onto standard 35 mm DIN rails conforming to EN 60715.
  • Ensure lock connection is engaged correctly during side-by-side terminal configuration via the integrated double slot-and-key system.
  • Use a standard screwdriver to actuate the spring-clamp terminals when routing field wiring.
  • Avoid installing in environments exceeding 95% non-condensing relative humidity.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
Loading product navigation…

What is the primary function of the Beckhoff EL4112-0010?

The Beckhoff EL4112-0010 is a 2-channel analog output terminal designed to output precise current signals ranging from -10 to +10 mA with 16-bit resolution.

Does the EL4112-0010 support synchronized EtherCAT operations?

Yes, it supports EtherCAT Distributed Clocks (DC), enabling highly synchronized output updates with a system precision of under 1 microsecond.

What is the maximum current load for the power contacts on this terminal?

The maximum current load capability of the power contacts on the EL4112-0010 is 10 A.

What is the protection rating and mounting method for this device?

The module features an IP20 protection rating and is designed for direct mounting onto standard 35 mm DIN rails (EN 60715).

Is the EL4112-0010 certified for hazardous industrial locations?

Yes, the terminal is ATEX-certified with the marking II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous areas.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...