Description

Facilitate seamless bidirectional data transmission between serial devices and high-level control architectures using the Beckhoff EL6002 EtherCAT terminal. This 2-channel serial communication interface enables the direct connection of up to two serial RS232 devices to the standard EtherCAT network. It integrates smoothly into decentralized systems, permitting flexible configuration of transmission parameters such as baud rate, parity, and stop bits directly via the EtherCAT master controller, eliminating the need for manual DIP switch configurations.

The unit features 500 V electrical isolation between the E-bus backplane and the RS232 signal lines to prevent ground loop damage and signal degradation in demanding industrial settings. Packaged in a compact housing, this module contains internal data buffers to ensure reliable asynchronous data transfer even under heavy system load.

Features

  • Two independent serial RS232 communication channels.
  • Standard 9-pin D-sub connectors for reliable physical terminal interface connections.
  • Flexible data transfer rates ranging from 300 to 115,200 baud.
  • Integrated data buffer with 864 bytes of receive buffer and 128 bytes of transmit buffer.
  • Direct power supply routing through the E-bus backplane.
  • Compact 24 mm housing with built-in signal status LEDs for simplified on-site diagnostic checks.

Applications

  • Integrating serial barcode readers, weight scales, and labeling machines.
  • Connecting legacy human-machine interfaces (HMIs) to EtherCAT systems.
  • Interfacing custom manufacturing instruments and specialized process sensors.
  • Decentralized industrial automation and general machinery control.

Technical Specifications

Manufacturer Beckhoff
Part Number/Model EL6002
Connection Technology 9-pin D-sub
Number of Channels 2
Interfaces 2 x RS232
Data Transfer Rates 300 to 115,200 baud (Default: 9600 baud, 8 data bits, no parity, 1 stop bit)
Cable Length Max. 15 m
Power Supply Via the E-bus
Current Consumption E-bus Typically 170 mA
Electrical Isolation 500 V (E-bus / signal voltage)
Data Buffer 864 bytes receive buffer, 128 bytes transmit buffer
Configuration No address setting required; configuration via the controller
Material Polycarbonate
Housing Design Compact terminal housing with signal LEDs
Dimensions (W x H x D) 24 mm x 100 mm x 52 mm
Weight Approx. 55 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, no condensation
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable

Connections and Interfaces

Connector Pin Standard RS232 Function (Typical Configuration)
Pin 1 DCD (Data Carrier Detect)
Pin 2 RxD (Receive Data)
Pin 3 TxD (Transmit Data)
Pin 4 DTR (Data Terminal Ready)
Pin 5 GND (Signal Ground)
Pin 6 DSR (Data Set Ready)
Pin 7 RTS (Request to Send)
Pin 8 CTS (Clear to Send)
Pin 9 RI (Ring Indicator)

Installation Guidelines

  • Mount the module onto a standard 35 mm DIN rail conforming to EN 60715 using the locking mechanism.
  • Ensure proper side-by-side terminal mounting by utilizing the double slot and key connection mechanics.
  • Observe IP20 protection guidelines; prevent moisture, excessive dust, and conductive particles from entering the enclosure.
  • Prior to wiring or installation, isolate the electrical system from all live power sources.

Compliance and Certifications

  • CE
  • UL
  • ATEX
Loading product navigation…

What data transfer rates are supported by the Beckhoff EL6002?

The EL6002 supports baud rates ranging from 300 to 115,200 baud. The default setting is 9600 baud, 8 data bits, no parity, and one stop bit.

How is the EL6002 module powered?

The module is powered internally through the E-bus backplane of the Beckhoff EtherCAT system, consuming a typical current of 170 mA.

What is the physical connection interface used by the EL6002?

It features two standard 9-pin D-sub connectors (RS232 interface) for direct and secure physical connection.

Is electrical isolation provided on this serial interface?

Yes, the EL6002 features 500 V of electrical isolation between the E-bus and the RS232 signal lines to prevent damage from potential differences.

What certificates does the EL6002 hold?

The module complies with CE, UL, and ATEX standards for industrial deployment.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...