Engineered for high-performance industrial networking, the Beckhoff EL6631-0010 serves as a specialized PROFINET RT device interface within decentralized EtherCAT Terminal systems. This gateway module enables seamless data exchange between EtherCAT and PROFINET RT controllers, mapping up to 1000 bytes of input and output process data directly onto the E-bus.

The module features an integrated 2-port switch designed for 100BASE-TX Ethernet connections via standard RJ45 connectors. This dual-port switched configuration simplifies line topology deployment in complex automation systems. Through hardware diagnostics and status LEDs, operators receive real-time visibility into E-bus communication status, network link activity, and protocol diagnostics.

Features

  • Dual-port switched Ethernet interface (100BASE-TX) via RJ45 connectors.
  • Supports PROFINET RT device protocol with Conformance Class B.
  • Handles up to 1 kbyte of input and 1 kbyte of output process data.
  • Integrated LLDP and SNMP functions for physical topology detection and network diagnostics.
  • Minimum RT cycle time of 1 ms.
  • Robust 500 V electrical isolation between E-bus and Ethernet interfaces.

Applications

  • Decentralized factory automation systems.
  • Machine building and modular assembly lines.
  • Interfacing PROFINET RT master controllers with high-speed EtherCAT networks.
  • Process control systems requiring distributed network topology bridging.

Technical Specifications

ManufacturerPart Number / ModelProtocolInterface TypeMax. Process Data SizeE-bus Current ConsumptionPower SupplyElectrical IsolationMax. Cable LengthOperating TemperatureStorage TemperatureRelative HumidityHousing MaterialDimensions (W x H x D)WeightInstallation Type
Beckhoff
EL6631-0010
PROFINET RT (Device)
100BASE-TX Ethernet (2 x RJ45 switched)
1 kbyte input / 1 kbyte output
typ. 400 mA
Via E-bus
500 V (E-bus / Ethernet)
Up to 100 m twisted pair
0 to +55 degC
-25 to +85 degC
95%, non-condensing
Polycarbonate
24 mm x 100 mm x 52 mm
approx. 75 g
35 mm DIN rail (EN 60715) with locking mechanism

Connections and Interfaces

Connector / Port Function
RJ45 Port 1 PROFINET RT / Ethernet interface (Switched port 1)
RJ45 Port 2 PROFINET RT / Ethernet interface (Switched port 2)
E-Bus Contacts Internal power supply and data exchange with EtherCAT master

Installation Guidelines

  • Mount vertically on standard 35 mm DIN rail conforming to EN 60715.
  • Ensure the double slot and key connection is aligned correctly with adjacent EtherCAT terminals.
  • Maintain clear ventilation channels above and below the terminal block to prevent thermal buildup.
  • Use shielded twisted pair (STP) cabling for network lines to limit electromagnetic interference.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • EMC Immunity/Emission: EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock Resistance: EN 60068-2-6 / EN 60068-2-27
Loading product navigation…

What is the primary function of the Beckhoff EL6631-0010?

The EL6631-0010 functions as a PROFINET RT device gateway within an EtherCAT Terminal system, allowing seamless communication between an EtherCAT master and a PROFINET RT master controller.

What is the maximum process data capacity of the EL6631-0010?

The module supports a maximum process data size of 1 kbyte input and 1 kbyte output.

Does the EL6631-0010 support network diagnostics?

Yes, it supports LLDP (Link Layer Discovery Protocol) and SNMP (Simple Network Management Protocol) for physical topology detection and advanced network diagnostics.

How is the EL6631-0010 terminal powered?

The module is powered internally via the standard EtherCAT E-bus, drawing a typical current of 400 mA.

What hazardous area certifications does the EL6631-0010 have?

The module is ATEX certified with the marking II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous locations when installed inside an appropriate enclosure.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les fluides : tutoriel pratique

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...