1 of 1

ERI2338-0001 | BECKHOFF | Boîte IO-Link

ERI2338-0001 | BECKHOFF | Boîte IO-Link

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : ERI2338-0001

  • Pays d'origine :Allemagne

  • Type de produit : Boîte IO-Link

  • Paiement : Virement bancaire, Western Union

  • Poids : 265g

  • Dimensions : 30 mm x 126 mm x 26.5 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for decentralized signal routing in demanding environments, the BECKHOFF ERI2338-0001 IO-Link box provides a highly adaptable interface for digital field devices. This robust module features eight digital channels that can be individually parameterized as inputs or outputs, allowing versatile configuration tailored to sensor or actuator requirements. Operating on the IO-Link V1.1 Class B specification, the unit transmits data at high-speed COM 3 rates of 230.4 kbaud.

Housed in a rugged, zinc die-cast enclosure, the module achieves ingress protection ratings of IP65, IP66, and IP67, enabling direct machine-mount installation without control cabinets. Complete electrical isolation between the logic supply (L+) and the actuator load power (P24) ensures system-wide signal integrity and fault isolation in high-noise industrial networks.

Features

  • Configurable 8-channel digital interface operating as inputs or outputs.
  • Robust zinc die-cast housing designed for high-stress industrial applications.
  • Supports IO-Link V1.1 Class B with a COM 3 transmission rate of 230.4 kbaud.
  • M8 screw-type connectors for reliable field device attachment.
  • Individually short-circuit proof outputs rated at 0.5 A per channel.
  • Adjustable input filtering range from 0 to 20 ms.
  • Complete galvanic isolation between L+ control power and P24 load voltage.

Applications

  • Decentralized assembly lines and robotics.
  • Automotive manufacturing and body shop applications.
  • Material handling systems and packaging machinery.
  • Field-level sensor/actuator integration in harsh physical environments.

Technical Specifications

ManufacturerPart Number / ModelCommunication ProtocolData Transfer RateNumber of ChannelsInput Filter TimeInput Voltage TypeInput CurrentSensor Supply VoltageLoad TypesRated Load VoltageMax. Output CurrentShort-Circuit CurrentCurrent Consumption (L+)Auxiliary Power CurrentElectrical IsolationHousing MaterialWeightDimensions (W x H x D)Operating TemperatureStorage TemperatureProtection RatingVibration / Shock ResistanceEMC Immunity / Emission
BECKHOFF
ERI2338-0001
IO-Link V1.1, Class B
230.4 kbaud (COM 3)
8 digital inputs or outputs (individually configurable)
3.0 ms (default), adjustable from 0 to 20 ms
"0" signal: -3 to +5 V, "1" signal: 11 to 30 V (EN 61131-2, type 3)
Typ. 3 mA (EN 61131-2, type 3)
From P24, max. 0.5 A total, short-circuit proof
Ohmic, inductive, lamp load
24 V DC (-15% / +20%)
0.5 A per channel from P24, individually short-circuit proof
Max. 1.5 A
Typ. 100 mA from L+
Typ. 20 mA + load
Yes (between L+ and P24)
Zinc die-cast
Approx. 265 g
30 mm x 126 mm x 26.5 mm
-25 to +60 degC
-40 to +85 degC
IP65, IP66, IP67 (conforms to EN 60529)
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Interface Type Connector Configuration Function
IO-Link Interface 1 x M12 plug, A-coded System integration and master-level communication
I/O Connections 8 x M8, screw type Digital sensor/actuator channel wiring

Installation Guidelines

  • Mount the unit directly onto a flat, rigid machine frame or profile using the two 3.5 mm diameter fixing holes designed for M3 screws.
  • Ensure all M8 and M12 mating cable connections are screwed tight to ensure the IP65/66/67 ingress protection remains fully intact.
  • Seal all unused M8 and M12 ports with certified protective caps to prevent dust and water entry.
  • Ensure proper system grounding paths in compliance with EN 61000-6-2 guidelines to guarantee optimal electromagnetic compatibility.

Compliance and Certifications

  • CE
  • UL

What is the primary communication standard of the Beckhoff ERI2338-0001?

The ERI2338-0001 complies with the IO-Link V1.1 Class B specification and supports communication speeds up to 230.4 kbaud (COM 3).

Are the channels on the ERI2338-0001 fixed or configurable?

The module contains 8 digital channels that can be individually configured as either inputs or outputs based on operational demands.

What protection rating does this IO-Link box offer?

It is constructed with a rugged zinc die-cast housing and is rated IP65, IP66, and IP67, making it suitable for direct mounting in harsh wet or dusty machine environments.

Is there electrical isolation in the ERI2338-0001?

Yes, there is full galvanic electrical isolation between the L+ logic supply and the P24 load voltage path.

What type of physical connectors are used for digital I/O?

The digital inputs and outputs use standard M8 screw-type connectors, while the IO-Link interface uses a 1 x M12 A-coded plug.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...