Designed for direct, machine-mount distributed deployment, the Beckhoff IP2002-B518 coordinates high-density localized outputs without the footprint or cost of protective control enclosures. This decentralized fieldbus box integrates 8 digital outputs operating at 24 V DC, utilizing CANopen protocol communications to optimize real-time control architectures. With integrated M12 T-junction connectors, this device enables clean line-topology bus configurations directly on physical machine frames. Wrapped in a ruggedized polyamide housing, it delivers reliable IP67 protection against moisture, dust, and continuous industrial vibrations.

Features

  • 8 Digital Outputs: Delivers up to 0.5 A per channel, fully compatible with resistive, inductive, and lamp load setups.
  • Integrated T-Connector: Built-in M12 5-pin male and female connectors enable straightforward physical looping of the CANopen bus.
  • Short-Circuit Diagnostics: Individual output channels feature electronic short-circuit protection to insulate localized faults.
  • Flexible Power Distribution: Dedicated M8 connections isolate control logic power (Us) from physical load power (Up).
  • Aggressive Environmental Rating: Rated for IP65/66/67 operation, securing signal paths in high-spray washdown zones.

Applications

  • Pneumatic Valve Block Control: Direct switching of manifold pilot valves on moving gantry assemblies.
  • Material Handling Conveyors: Localized routing of sorting diverters, stop gates, and indicator lights.
  • Automotive Assembly Tooling: Robotic end-effector output distribution where control enclosure space is non-existent.
  • Packaging and Bottling Machinery: Multi-station actuator triggering in high-moisture production zones.

Technical Specifications Table

Parameter Value / Specification
Manufacturer Beckhoff
Model Number IP2002-B518
Module Type 8-Channel Digital Output Fieldbus Box
Protocol / Interface CANopen (16 Tx / 16 Rx PDOs supported)
Supported Baud Rates 10 kbaud to 1 Mbaud (automatic detection)
Number of Outputs 8 (single-wire connection)
Nominal Output Voltage 24 V DC (-15 % / +20 %)
Max. Output Current 0.5 A per channel (individually short-circuit proof)
Electrical Isolation 500 V (Control voltage to fieldbus)
Control Voltage Supply (Us) 24 V DC, typical 45 mA current consumption
Fieldbus Connection 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) (Integrated T-Connector)
Power Supply Feed 1 x M8 male (4-pin); Downstream loop: 1 x M8 female (4-pin)
Housing Material Polyamide PA6 (XXL housing)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Class IP65 / IP66 / IP67 (conforms to EN 60529)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Connector / Interface Pin Number Signal Assignment
CANopen Fieldbus (M12) Pin 1 CAN_SHLD (Shield)
Pin 2 V+ (Optional External Power)
Pin 3 CAN_GND (Ground)
Pin 4 CAN_H (Signal High)
Pin 5 CAN_L (Signal Low)
Power Supply Feed (M8) Pin 1 Us +24 V DC (Control Voltage for Electronics)
Pin 2 Up +24 V DC (Load Voltage for Digital Outputs)
Pin 3 GNDs (Control Ground)
Pin 4 GNDp (Load Ground)

Empirical Engineering Insights

Alternative Models & Compatibility

The B518 variant serves as an drop-in optimization over legacy B510 fieldbus boxes. Because the IP2002-B518 integrates the T-connector directly within its molded housing, it completely replaces the requirement for external "Z1001" network splitter adapters, decreasing field cabling clutter and potential points of ingress failure.

Application Pitfalls & Engineering Notes

While each individual channel features short-circuit current protection peaking at approximately 1.5 A under fault conditions, the cumulative load across all 8 output channels must not exceed the maximum current rating of the feeding M8 terminal (typically capped at 4 A total across Up). Ensure appropriate current-budget configurations are calculated for simultaneously active inductive loads.

Commissioning & Wiring Tips

To access the decimal rotary node-ID configuration switches, remove the protective cover plate using a small flat screwdriver. Ensure this plate is re-seated with its sealing gasket completely flush to preserve the IP67 integrity. Additionally, note that this module does not integrate internal CAN termination resistors; a physical M12 termination plug must be added at the terminal physical drop-point of the network.

Installation Guidelines

CRITICAL WARNING: Ensure all power distribution lines (Us and Up) are fully de-energized prior to connecting or disconnecting any M8 or M12 cables. Connecting active power lines to IP-series modules can result in contact-arc damage and compromise internal diagnostic logic.
1
Mechanical Mounting: Mount the module directly onto a flat machinery support structure using the two 3.5 mm diameter fixing points using M3 screws. Ensure no torsional stress is applied to the PA6 housing.
2
Configure Node ID: Unscrew the protective cover. Using a rotary switch tool, set the correct CANopen Node ID. Verify the baud rate setting is configured correctly (defaulting to auto-detection). Re-seal the cover.
3
Bus & I/O Connections: Connect the M12 fieldbus lines to the integrated T-connector ports. Tighten the knurled metal collars hand-tight (0.6 Nm torque recommended) to guarantee environmental protection.
4
Power Integration: Hook up the incoming 4-pin M8 feed. If multiple boxes are in line, loop from the downstream M8 female connector to the subsequent device.
Loading product navigation…

What is the function of the integrated T-connector on the IP2002-B518?

The integrated T-connector consists of an M12 plug and an M12 socket, allowing the CANopen fieldbus cable to loop through the module directly. This eliminates the need for separate external T-splitters on the line.

Are the control and load voltages electrically isolated?

Yes, there is 500 V electrical isolation between the control voltage electronics (Us) and the CANopen fieldbus network, reducing the risk of ground loops and signal interference.

How do you set the CANopen node address on this module?

The address is set manually using two decimal rotary switches located under a protective screw-retained cover plate on the front of the polyamide housing.

What happens if a single digital output channel is short-circuited?

Each of the 8 digital outputs is individually short-circuit proof. If a fault occurs, the module limits the current to typically 1.5 A and isolates the fault locally without shutting down the entire block.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...