1 of 1

KL2761 | BECKHOFF | Bornier de bus

KL2761 | BECKHOFF | Bornier de bus

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : KL2761

  • Pays d'origine :Allemagne

  • Type de produit : Bornier de bus

  • Paiement : Virement bancaire, Western Union

  • Poids : 60g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Realize stable, fieldbus-controlled power regulation with the Beckhoff KL2761 1-channel universal dimmer terminal. Engineered for integration within the standard Beckhoff K-bus terminal assembly, this module regulates the power of lighting devices and other AC loads up to 600 VA. Utilizing automatic load detection, it handles ohmic, inductive, and capacitive loads via advanced phase control mechanisms. This terminal enables precise, system-level brightness and power adjustments directly from the master controller, offering scalable distributed automation capabilities for diverse environmental and process control applications.

Features

  • Single-channel AC dimmer with integrated fieldbus functionality.
  • Automatic load type detection (handles ohmic, inductive, capacitive, and lamp loads).
  • Four-wire connection technology for secure, direct field wiring.
  • High-resolution control adjustable to 1% intervals.
  • Robust electrical isolation between K-bus logic and field voltage levels.
  • Compact 12 mm housing width maximizing DIN rail space efficiency.
  • Fully compatible with standard KSxxxx series pluggable wiring systems.

Applications

  • Commercial and industrial building automation systems.
  • Integrated lighting and stage illumination controls.
  • Variable power regulation for process heating and small AC motor controls.
  • Infrastructure power management and distribution panels.

Technical Specifications

Manufacturer BECKHOFF
Part Number KL2761
Connection Technology 4-wire
Number of Outputs 1
Nominal Voltage 230 V AC (50 Hz)
Mains Voltage 230 V AC (50 Hz)
Rated Output 600 VA (W)
Rated Current Max. 2.7 A
Load Type Ohmic, inductive, or capacitive (not mixed), lamp load, automatic load detection
Max. Output Current 2.7 A
Short-Circuit Current 20 to 40 A
Control Type Phase control
Resolution 1%
Electrical Isolation 500 V (K-bus/field voltage), 3750 V AC (1 min.)
Leakage Current (OFF State) < 1 mA
Current Consumption Power Contacts Load only
Current Consumption K-Bus Typ. 95 mA
Bit Width in Process Image Output: 1 x 16-bit data (1 x 8-bit control/status optional)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Weight Approx. 60 g

Installation Guidelines

  • Mounting: Snap directly onto standard 35 mm DIN rail (EN 60715) with secure physical latching.
  • Wiring: Isolate all field power prior to wiring. Utilize the 4-wire terminal connections. For pluggable terminal blocks, use KSxxxx compatible modules.
  • Thermal Management: Maintain clean convective airflow around the unit. Do not exceed the operating range of 0 to +55 degC.
  • Grounding: Ensure the mounting rail is properly grounded to ensure correct EMI protection performance.

Compliance and Certifications

  • CE
Loading product navigation…

What types of electrical loads are compatible with the Beckhoff KL2761?

The KL2761 supports ohmic, inductive, and capacitive loads (non-mixed types) as well as lamp loads, utilizing integrated automatic load type detection.

What is the maximum rated current and power output of the KL2761 terminal?

The module features a maximum output current rating of 2.7 A and a nominal rated power output of 600 VA (W) at 230 V AC (50 Hz).

What type of connection technology is used by the KL2761?

The terminal utilizes standard 4-wire connection technology and is compatible with pluggable wiring via KSxxxx series terminal housings.

Is the KL2761 electrically isolated from the K-bus?

Yes, it provides 500 V electrical isolation between the K-bus logic circuit and the field voltage, along with 3750 V AC isolation for 1 minute.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...