KL4022 | BECKHOFF | Bornier de bus

KL4022 | BECKHOFF | Bornier de bus

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : KL4022

  • Pays d'origine :Allemagne

  • Type de produit : Bornier de bus

  • Paiement : Virement bancaire, Western Union

  • Poids : 1000g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for integration into standard K-bus networks, the Beckhoff KL4022 enables high-precision processing of current loop control signals. This terminal converts 12-bit digital values from the automation controller into isolated analog current outputs within the standard 4 to 20 mA range. Its single-ended topology, compact housing, and low conversion latency make it highly suitable for demanding industrial actuator control, valve positioning, and motor drive setpoint configuration.

Features

  • Dual-channel analog output configuration utilizing single-ended common ground architecture.
  • Robust 12-bit digital-to-analog conversion delivering dependable loop precision.
  • High-integrity electrical isolation of 500 V between the internal K-bus and field signals.
  • Rapid internal conversion sequence with a typical processing time of 1.5 milliseconds.
  • Efficient power distribution leveraging integrated 24 V DC power contacts on the backplane.

Applications

  • Electro-pneumatic and electro-hydraulic proportional valve positioners.
  • Frequency inverter and variable speed drive (VSD) speed references.
  • Distributed SCADA and process control instrumentation interfaces.
  • Industrial boiler and heating element loop controller feedback.

Technical Specifications

Parameter Value / Rating
Manufacturer Beckhoff Automation
Model Number KL4022
Signal Range 4 to 20 mA
Number of Channels 2
Resolution 12-bit
Load Impedance Less than 500 Ohm
Conversion Time approx. 1.5 ms
Output Error Less than +/- 0.1% (relative to full-scale value)
Power Supply 24 V DC via power contacts (or 15 V DC via KL9515 supply terminal)
K-Bus Current Consumption typ. 75 mA
Electrical Isolation 500 V (K-bus / signal voltage)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Country of Origin Germany
Weight approx. 80 g
Shipping Weight (Calculated) 0.25 kg

Connections and Interfaces

Terminal Point Signal Assignment Description
1 OUT 1 Analog Output Channel 1 (+)
5 0V (1) Analog Output Channel 1 ground (-)
2 OUT 2 Analog Output Channel 2 (+)
6 0V (2) Analog Output Channel 2 ground (-)
3 +24 V Power Contact Connection (+24 V DC)
7 0 V Power Contact Connection (0 V DC)
4 Shield Shield contact point (connected to DIN rail)
8 Shield Shield contact point (connected to DIN rail)

Empirical Engineering Insights

Alternative Models & Compatibility

The KL4022 utilizes Beckhoff's legacy K-bus backplane communication system. If transitioning to an EtherCAT infrastructure, the direct equivalent is the EL4022. Note that EL-series terminals utilize the E-bus and cannot reside on standard KL-series couplers (e.g., BK9000, BK3120) without active E-bus/K-bus converter couplers.

Application Pitfalls & Engineering Notes

Since the KL4022 is a single-ended terminal sharing a common internal ground loop, noise injected into the 0 V signal reference on one loop can cause cross-talk or offset drift on the secondary channel. For field installations with significant ground potential differences, isolated signal conditioning barriers must be installed between the KL4022 and the end-actuator to prevent loop degradation.

Commissioning & Wiring Tips

Ensure that shielding is correctly terminated. Terminal points 4 and 8 are connected to the mounting rail. To guarantee sufficient noise rejection, the standard 35 mm DIN rail must be connected to the central control cabinet ground with low-impedance copper braided strap. Ensure K-bus power contacts are adequately populated with 24 V DC; voltage drops below 18 V DC will cause conversion errors or terminal fault signals within TwinCAT.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Isolate and lock out all power supplies to the system before inserting or removing K-bus components. Modifying the physical configuration or terminal assembly while the power is active can induce voltage spikes, resulting in damage to the internal bus driver circuitry or physical terminal contacts.

1

Mount the terminal onto the 35 mm DIN rail (EN 60715) by sliding the terminal's rear slot onto the rail guide until the locking tab audibly clicks.

2

Align the terminal laterally with the adjacent Bus Terminal block to engage the tongue-and-groove joint and establish continuous electrical contact via the side-mounted gold contacts.

3

Insert field connection cables into the cage-clamp connectors using an appropriate industrial screwdriver. Release the mechanism to secure wire connection.

4

Connect the analog loop shielding directly to contacts 4 or 8 to guarantee direct path grounding through the DIN rail structure.

Loading product navigation…

What is the key difference between the KL4022 and EL4022 modules?

The KL4022 operates on the K-bus backplane protocol for classic bus couplers, whereas the EL4022 communicates via E-bus for EtherCAT networks. They cannot be placed on the same terminal strip without a dedicated converter terminal.

Does this terminal require an external loop power supply for the current signal?

The KL4022 extracts its power from the integrated 24 V DC power contacts. If the power Contacts are not energized, or if isolation is required, you must insert a power supply terminal like the KL9100 or KL9200 immediately to its left.

How is the 12-bit resolution represented inside the controller software?

The 12-bit value is loaded into a 16-bit register as a left-aligned integer. The remaining 4 least-significant bits are ignored by the internal digital-to-analog converter.

Are the two output channels of the KL4022 electrically isolated from each other?

No, both channels share a common internal ground reference (0 V) and are single-ended. However, they are both electrically isolated up to 500 V from the K-bus logic circuitry.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...