Description

Designed to facilitate seamless integration of utility metering devices, the Beckhoff KL6781 operates as a single-channel M-Bus master terminal within the standard Beckhoff Bus Terminal system. This module enables direct, bidirectional communication with up to 40 standard M-Bus loads, such as heat, water, electricity, or gas meters, over a single bus segment without requiring external level converters. Operating in master-slave mode via polling, the KL6781 transmits data standard M-Bus physics, enabling consolidated energy management and resource tracking directly from the TwinCAT control environment.

The terminal features a 24-byte process image for inputs and outputs, allowing robust data transfer rates ranging from 300 to 9600 baud. Integration is streamlined through the TwinCAT PLC M-Bus library, which provides specialized function blocks for rapid field configuration. With built-in short-circuit protection and 500 V electrical isolation between the K-bus and the M-Bus physics, the module ensures robust operation and system-wide protection against electrical faults in harsh industrial or commercial environments.

Features

  • Single-Channel Architecture: Dedicated M-Bus interface supporting up to 40 standard M-Bus loads (1.5 mA current consumption per load).
  • Flexible Baud Rates: Configurable data transfer rates from 300 to 9600 baud (default transmission set to 2400 baud).
  • Electrical Isolation: Complete 500 V isolation barrier safeguarding the internal K-bus from the M-Bus network.
  • Integrated Protection: Full short-circuit proof design to prevent module failure during field wiring faults.
  • Software Compatibility: Programmed and configured directly through TwinCAT using official M-Bus PLC function blocks.

Applications

  • Commercial and industrial building automation systems (BAS).
  • Sub-metering networks for monitoring water, gas, steam, and electricity consumption.
  • Energy management systems (EMS) compliant with ISO 5001 standards.
  • District heating stations and utility billing infrastructure.

Technical Specifications

CategoryParameterValue
Administrative Manufacturer Beckhoff Automation
Part Number/Model KL6781
Product Series Bus Terminal System (KL Series)
Communication & Bus Technology M-Bus
Data Transfer Standard M-Bus physics
Number of Channels 1
Maximum Connected Loads 40 standard loads (1.5 mA each)
Data Transfer Rates 300 to 9600 baud (default: 2400 baud)
Bus Access Master-slave mode (polling)
Electrical Data Nominal Voltage 24 V DC (-10% / +8%)
Current Consumption (K-bus) Typically 65 mA
Current Consumption (Power Contacts) Maximum 250 mA
Protection & Safety Short-Circuit Protection Yes
Electrical Isolation 500 V (K-bus / M-Bus)
Process Image Bit Width 24 bytes input / 24 bytes output
Environmental & Mechanical Weight Approx. 60 g
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Relative Humidity 95%, non-condensing
Standards & Approvals Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Certifications & Marks CE, UL

Connections and Interfaces

Terminal Point Signal/Function Description
1 M+ M-Bus Connection (+)
2 Shield Shielding / Functional Ground
3 +24 V DC External Power Supply (+)
5 M- M-Bus Connection (-)
7 0 V DC External Power Supply (0 V)

Installation Guidelines

  • Mounting: Mount the terminal vertically on standard 35 mm DIN rails (EN 60715) within an IP20-rated enclosure or control cabinet.
  • Wiring: Keep maximum cable lengths on the M-Bus segment below 300 meters. Use shielded twisted-pair (STP) cabling for optimal noise immunity.
  • Grounding: Connect the shield connection point directly to a low-impedance functional ground or DIN rail clamp.
  • Ventilation: Ensure a clearance of at least 30 mm above and below the terminal block to maintain normal operating temperatures between 0 and 55 degC.
Loading product navigation…

What is the primary function of the Beckhoff KL6781?

The Beckhoff KL6781 acts as a single-channel M-Bus master terminal within a Beckhoff Bus Terminal system, enabling direct integration of M-Bus compliant utility meters (water, gas, electricity, heat) without external level converters.

How many M-Bus devices can be connected to the KL6781 terminal?

The KL6781 supports up to 40 standard M-Bus loads, assuming each connected device consumes a standard current of 1.5 mA.

What software is used to configure the KL6781?

Configuration is handled in TwinCAT using the official TwinCAT PLC M-Bus library, which contains dedicated function blocks for communicating with the meters.

Is the KL6781 protected against field wiring faults?

Yes, the module is short-circuit proof and features 500 V electrical isolation between the inner K-bus electronics and the external M-Bus physics.

What is the maximum cable length supported by the M-Bus line on the KL6781?

The terminal supports a maximum M-Bus cable length of up to 300 meters.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les fluides : tutoriel pratique

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...