1 de 1

VFD450CP43S-21 | DELTA | Variateur vectoriel pour ventilateur/pompe

VFD450CP43S-21 | DELTA | Variateur vectoriel pour ventilateur/pompe

Il ne reste que 10 article(s) en stock
  • Fabricant : Delta Electronics

  • N° de produit : VFD450CP43S-21

  • Pays d'origine :États-Unis

  • Type de produit : Variateur à Commande Vectorielle pour Ventilateur/Pompe

  • Paiement : Virement bancaire, Western Union

  • Poids : 40000g

  • Dimensions : 11.02 in x 24.19 in x 10.04 in

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed specifically for energy-efficient HVAC and pumping systems, the VFD450CP43S-21 is a high-performance variable frequency drive belonging to the premium Delta Electronics CP2000 series. This unit delivers precise sensorless vector control optimized for variable torque loads such as industrial fans, blowers, and centrifugal pumps. By dynamic adjustment of motor speed relative to real-time load demands, it significantly reduces energy consumption and mechanical wear across industrial processes.

The drive features an integrated PLC capability, allowing engineers to program custom logic sequences directly on the device without requiring external controllers. It supports multi-pump control algorithms out of the box, facilitating automated circulation, redundancy, and pressure control schemes. Housed in a durable wall-mount enclosure, the drive maintains steady performance under challenging operating conditions while offering straightforward integration into modern industrial networks.

Features

  • Advanced sensorless vector control (SVC) and V/F control modes tailored for variable torque applications.
  • Built-in PLC functionality with program capacity to execute localized control sequences and logic.
  • Multi-pump master/slave configurations supporting fixed-time and fixed-amount circulation.
  • Integrated PID feedback control with sleep and wake functions to optimize water and air delivery systems.
  • Modbus communication interface as standard for seamless connection to PLC and DCS architectures.
  • User-friendly LCD keypad providing real-time parameter configuration and fault-monitoring diagnostics.

Applications

  • HVAC air handling units (AHUs), ventilation fans, and cooling towers.
  • Municipal water supply systems and wastewater treatment pumping stations.
  • Industrial boiler feed pumps and recirculation loops.
  • Dust collection systems and centralized exhaust blowers.

Technical Specifications

ManufacturerPart Number / ModelSeriesApplicable Motor CapacityRated Output CurrentInput Voltage / PhaseInstallation TypeIP Protection LevelNEMA Protection LevelOperating TemperatureDimensions (W x H x D)Weight
Delta Electronics
VFD450CP43S-21
CP2000
60 HP (45 kW)
73 Amps
460V 3-Phase
Wall Mount
IP20
NEMA 1
-10 to 50 degC (without derating)
11.02 in x 24.19 in x 10.04 in
40 Kg

Installation Guidelines

For optimal reliability and safety, ensure the VFD450CP43S-21 is installed vertically on a non-combustible, flat vertical wall. Maintain a minimum clearance of 50 mm on both sides and 120 mm above and below the drive to ensure unobstructed airflow for the cooling fans. Since this module carries an IP20/NEMA 1 rating, it must be installed in a clean, dry, and dust-free environment protected from direct sunlight, corrosive gases, and moisture condensation.

Always connect the grounding terminal to a dedicated, low-impedance ground point (less than 10 ohms for 400V class systems) to minimize electromagnetic interference (EMI). Shielded motor cables are highly recommended to prevent cross-talk and RF noise emission into adjacent control instrumentation.

Loading product navigation…

What is the primary power rating of the Delta VFD450CP43S-21?

The VFD450CP43S-21 is rated for an applicable motor capacity of 60 HP (45 kW) with a rated continuous output current of 73 Amps.

What input voltage configuration does this variable frequency drive require?

This drive requires a 460V 3-phase input voltage supply.

What are the protection ratings of this physical unit?

The drive features an IP20 protection level and is rated for NEMA 1 indoor installations.

Can the VFD450CP43S-21 manage multiple pumps simultaneously?

Yes, the CP2000 series includes integrated multi-pump control algorithms for fixed-time and fixed-amount circulation directly via its built-in PID and PLC functions.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...