1 of 3

Bently Nevada 991-01-XX-02-05 Custom 2-Wire Thrust Transmitter

Bently Nevada 991-01-XX-02-05 Custom 2-Wire Thrust Transmitter

Only 8 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 991-01-XX-02-05

  • Country of origin:United States

  • Product Type: Thrust Transmitter

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 440g

  • Dimensions: 7.3cm x 5cm x 10cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

 

Description

The Bently Nevada 991-01-XX-02-05 is a specialized, loop-powered custom 2-wire thrust transmitter designed for industrial machinery protection within spatial constraints. This integrated field instrument combines the functions of a proximity sensor conditioner and signal processing circuitry into a single robust module, transforming raw non-contacting probe inputs directly into a standard 4-24 mA analog current loop output proportional to linear shaft axial position or thrust displacement. The 991-01-XX-02-05 interfaces directly with a proximity transducer probe array to track microscopic rotor movement relative to fluid-filmed thrust bearing faces. By outputting a continuous 4-20 mA current loop directly to a distributed control system (DCS), programmable logic controller (PLC), or asset monitoring platform, it enables real-time over-travel alerts and automatic emergency trip logic without requiring an intermediate Proximitor sensor housing. The transmitter features an isolated front-panel buffered voltage terminal to provide raw dynamic transducer signals to analytical instruments, tailored mounting dimensions, and a potted electronics package for high reliability under harsh plant conditions.

Features

  • Integrated 2-wire system delivering a direct 4-20 mA linear current output proportional to axial thrust displacement.
  • Onboard independent buffered voltage terminal providing unconditioned transducer waveforms directly to external field diagnostic tools.
  • Potted solid-state enclosure protecting internal component blocks against vibration, moisture, and particulate ingress.
  • High-density design enabling direct connection to host analog input cards without intermediate signal conditioners.
  • Tailored hardware option configurations supporting specialized mounting brackets and specialized industrial deployment sectors.

Applications

  • High-accuracy axial displacement and thrust bearing wear protection on heavy-duty centrifugal process compressors.
  • Standalone rotor position monitoring and emergency trip safety loops on high-pressure main boiler feed pumps.
  • Continuous machinery health tracking and predictive maintenance loops on steam or gas utility turbines.

Ordering Information

Detail Product Ordering Reference
Base Model Designation 991 (Thrust Transmitter)
Full Module Model Code 991-01-XX-02-05
Full Option Suffix Configuration -01 (Full-Scale Linear Range Option)
  -XX (Variable Custom Options Selection Suffix)
  -02 (Mounting Hardware / Bracket Base Option)
  -05 (Specialized Custom Configuration Suffix)

Technical Specifications

Parameter Detail
Manufacturer Bently Nevada (Baker Hughes)
Model Designation 991-01-XX-02-05
Transmitter Product Type Custom 2-Wire Proximity Thrust / Axial Position Transmitter
Electrical Interface Profile Loop-powered 2-wire current loop architecture
Analog Current Loop Output 4-20 mA DC linear output proportional to shaft axial travel
Dynamic Diagnostic Port Front-mounted buffered voltage output terminal for local analyzer plug-in
System Power Input Range Nominal 24 VDC external power supply loop
Transducer Input Compatibility Non-contacting proximity transducer probe assembly
Mounting Hardware Suffix 02 Option Specific Base Configuration
Custom Modification Suffix 05 Custom Variant Package
Chassis Mechanical Envelope Corrosion-resistant anodized aluminum housing with integrated terminal strips
Hardware Core Layout Low-profile compact footprint optimized for high-density side-by-side array mounting
Operational Weight Reference Industrial standard field transmitter assembly weight

Connections/Interfaces

Terminal Point Designation Terminal Function Assignment
+ / Loop Positive DC Loop Voltage Input Supply / Signal Connection
- / Return Negative Return / Current Loop Signal Output Connection
BUF / Dynamic Dynamic Raw Voltage Output Signal Point (For portable vibration/position meters)
COM / Ground Common Circuit Ground reference terminal line
Probe Input Dedicated connection terminal block input for external proximity probe lead

Installation Guidelines

  • Chassis Base Mounting: Affix the transmitter enclosure securely to a clean, flat, unpainted panel backplate inside an industrial junction box. Verify robust mechanical attachment to ensure stable grounding across the metal panel.
  • Proximity Probe Interconnection: Connect the external non-contacting proximity transducer coaxial lead wire straight to the designated probe input terminal block. Keep the input wiring pathways separate from high-current motor supply feeds to minimize electromagnetic interference.
  • Loop Circuit Verification: Prior to energizing the 24 VDC loop network, double-check all circuit resistances and power supply load parameters to avoid voltage drops or electronic component strain.
  • Diagnostic Contact Protection: Keep the buffered voltage output terminal ports sealed with protective caps when field diagnostic test equipment is not actively attached to safeguard the diagnostic contacts against ambient corrosion.
Key Features:

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Recently Viewed Products

Technical knowledge

What Is a VFD? Variable Frequency Drives That Actually Move the Needle

A VFD turns fixed-frequency mains into controlled voltage and frequency so AC motors match real load—cutting pump and fan energy while tightening torque, soft-start, and braking behavior.

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...