Description

The Honeywell 10004/1/1 is an isolated RS485/RS422 communication interface module designed for serial data exchange within the Honeywell Fail Safe Control (FSC) safety system architecture. Operating within the Central Part (CP) rack assembly, the module establishes secure, galvanically isolated serial communication channels between the FSC safety logic solver and external automation platforms, such as supervisory Control and Data Acquisition (SCADA) systems, Distributed Control Systems (DCS), or peer programmable logic controllers.

Engineered for safety-critical industrial applications, the Honeywell 10004/1/1 isolates external network noise, ground loops, and electrical transients from the core system buses. By maintaining physical and electrical separation, it prevents external electrical faults from compromising the central processing units or diagnostic subsystems. The module provides the underlying serial hardware layer required for high-availability system topologies, support for long-distance serial runs, and multidrop network configurations in harsh operating environments.

Features

  • Galvanic Isolation: Provides electrical isolation for serial signals to protect the Central Part backplane from field noise, ground loops, and voltage surges.
  • Dual RS485 / RS422 Capability: Configurable interface architecture supporting multidrop RS485 differential bus topologies and point-to-point RS422 configurations.
  • System Bus Integration: Direct interface compatibility with FSC Central Part system racks and backplane communication structures.
  • Industrial Safety Architecture: Standardized Central Part module design built to conform with safety-instrumented system (SIS) standards and industrial safety control requirements.
  • Extended Noise Immunity: Differential signaling layout optimized for long-distance communication links in high electromagnetic interference (EMI) environments.

Applications

  • DCS / SCADA Subsystem Integration: Interfacing FSC safety instrumented systems with high-level plant control and monitoring systems.
  • Peer-to-Peer Controller Networking: Connecting multiple FSC Central Part racks or auxiliary control networks via isolated serial links.
  • Sequence of Events (SOE) Data Transmission: Transmitting diagnostic, alarm, and timestamped event data to external historian servers.
  • Remote Terminal Unit (RTU) / Field Device Communication: Serial data collection from remote field telemetry or specialized process equipment.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 10004/1/1
Product Type Communication Module (COM)
Interface Type Isolated RS485 / RS422 Interface
System Architecture Honeywell Fail Safe Control (FSC) Central Part
Isolation Isolated interface circuitry
Operating Temperature 0 degC to 60 degC
Storage Temperature -25 degC to 80 degC
Operating Humidity 95% relative humidity (non-condensing)
Shock Resistance 15 G in 3 axes (11 ms duration)
Vibration Resistance 10–57 Hz (0.075 mm displacement), 57–150 Hz (1 G)

Installation Guidelines

  1. Pre-Installation Safety Verification: Ensure power to the FSC Central Part rack is switched off and lock-out/tag-out (LOTO) procedures are followed prior to inserting or removing the module.
  2. Rack Slot Verification: Confirm the correct Central Part rack slot allocation in accordance with the FSC system configuration software before hardware insertion.
  3. ESD Precautions: Wear a grounded electrostatic discharge (ESD) wrist strap while handling the module to prevent damage to internal sensitive components.
  4. Physical Mounting: Align the module card edges with the Central Part rack guides, sliding the module firmly into place until the rear backplane connectors fully seat. Secure the front retaining fasteners.
  5. Wiring and Shielding: Route shielded twisted-pair (STP) cable to the module's serial interface connector. Ensure signal shields are properly grounded at a single protective earth point to avoid ground loops.
  6. Interface Termination: Verify that appropriate RS485/RS422 line termination resistors are installed at the physical end nodes of the serial communication bus to minimize reflections.

FAQ

What is the primary function of the Honeywell 10004/1/1 module?

The module acts as an isolated RS485/RS422 communication interface within the Honeywell FSC system, allowing the central processor to communicate with external serial networks, SCADA systems, or auxiliary control hardware while protecting the system backplane from electrical noise.

Where is the 10004/1/1 module installed within an FSC system?

The module is designed for installation directly into designated slots of the FSC Central Part (CP) rack, connecting to the system backplane to handle serial interface operations.

Why is signal isolation important for the Honeywell 10004/1/1 interface?

Galvanic isolation breaks ground loops and prevents external voltage spikes or industrial electrical noise on field serial wiring from damaging the FSC central processor and core backplane electronics.

What serial protocol hardware standards does the module support?

The device provides physical hardware layer support for differential isolated RS485 multidrop networks as well as point-to-point or multi-point RS422 communication topologies.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 5
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.

PLC I/O Modules: Wiring, Load, and Isolation Checks

A field checklist for matching PLC digital and analog I/O to sensors, loads, commons, isolation groups, filters, and replacement settings.