Engineered for precise industrial process automation, the Q68AD-G functions as a channel-to-channel isolated analog-to-digital conversion module designed for the Mitsubishi MELSEC-Q Series PLC platform. This module features eight independent channels, providing robust electrical separation between inputs to eliminate ground loops and minimize signal interference in complex electrical environments.

Each channel can be independently configured to accept either voltage or current signals, accommodating standard industrial sensors and transmitters. The integration of high-resolution digital conversion options and dedicated scaling functions allows for precise data acquisition, delivering reliable metrics directly to the master controller backplane. External connections are consolidated through a high-density 40-pin interface, ensuring secure and compact field wiring.

Features

  • Complete channel-to-channel isolation using internal transformer technology to safeguard control circuitry.
  • Eight independent analog input channels supporting mixed voltage and current configurations.
  • Dual resolution operation settings: Normal resolution mode and High resolution mode for granular tracking.
  • Fast conversion rate with a sampling cycle of 10 ms per active channel.
  • Broad signal range support including standard industrial ranges (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 0 to 20 mA, and 4 to 20 mA).

Applications

  • Power generation and substation telemetry monitoring.
  • Oil and gas refinery instrumentation.
  • Water and wastewater treatment facility chemical dosage monitoring.
  • Steel manufacturing plant temperature and pressure tracking.

Technical Specifications

Manufacturer Mitsubishi Electric
Part Number / Model Q68AD-G
Module Type Channel-to-Channel Isolated Analog-to-Digital Conversion Unit
Analog Inputs 8 points (8 channels)
Voltage Input Range DC -10 to +10 V (Input resistance: 1 MOhm or more)
Current Input Range DC 0 to 20 mA (Input resistance: 250 Ohm)
Sampling Cycle 10 ms / channel
Response Time 20 ms
Absolute Maximum Input Voltage: ±15 V, Current: ±30 mA
Isolation Method Transformer isolation between input terminals and PLC power supply, and between individual analog input channels
Withstand Voltage (Input to Backplane) 500 V AC rms for 1 minute
Withstand Voltage (Channel to Channel) 1000 V AC rms for 1 minute
Insulation Resistance 10 MOhm or more at 500 V DC
Temperature Coefficient ±71.4 ppm / degC (0.00714% / degC)
Occupied I/O Points 16 points (I/O assignment: 16 points intelligent function module)
Internal Current Consumption (5 V DC) 0.46 A
External Dimensions (H x W x D) 102 mm x 27.4 mm x 90 mm
Weight 0.16 kg

Connections and Interfaces

Interface Element Specification / Compatibility
External Wiring Interface 40-pin connector
Compatible Connectors A6CON1, A6CON2, A6CON4 (sold separately)

Installation Guidelines

  • Always power down the MELSEC-Q base unit before mounting or removing the module to prevent electrical shock or module damage.
  • Ensure that signal cables are routed away from high-voltage AC lines and motor drive cables to reduce electromagnetic interference.
  • To satisfy isolation requirements, verify that the external grounding terminal is properly connected to the functional earth of the cabinet.
  • Securely tighten any connector screws on the 40-pin interface to maintain stable contact resistance during thermal cycles.

Compliance and Certifications

  • CE Compliant
  • UL Listed
Loading product navigation…

What is the primary benefit of the channel-to-channel isolation on the Q68AD-G?

Channel-to-channel isolation provides individual electrical separation for all 8 inputs. This prevents ground loops, reduces signal cross-talk, and protects the internal system circuitry from external electrical surges.

Which external connection plugs are required for the Q68AD-G module?

The module utilizes a 40-pin connector. It is compatible with Mitsubishi A6CON1, A6CON2, and A6CON4 connectors, which are sold separately.

What are the voltage and current input ranges supported by this card?

The Q68AD-G supports DC voltage inputs from -10 to +10 V, and DC current inputs from 0 to 20 mA (including standard 4 to 20 mA configurations).

What is the sampling rate of the Q68AD-G analog-to-digital module?

The module features a conversion sampling speed of 10 ms per active channel.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les fluides : tutoriel pratique

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...